Gateways
Industrial Gateway Protocol Converter 1.Modbus-RTU protocol to FF protocol 2.Compliant with FF standard 3.Support LinkMaster function 4.Support standard DD specification 5.Support up to four Modbus devices
-
Hot
Fieldbus Gateway HART to FF
1. HART protocol to FF Protocol
Email Details
2. Support HART5/6/7 Protocol
3. Support ITK 6.1.1
4. Support Up to four HART Salve Devices
5. Support 4AI and 1 PID FUNCTION BLOCK -
Hot
MODBUS To PA Gateway
MODBUS To PA Gateway The product realizes the converter function from Modbus RTU to PROFIBUS PA, and it shall multiple devices with Modbus RTU protocol to PROFIBUS PA network.
Email Details
1. Modbus-RTU protocol to PROFIBUS PA protocol
2. Support PA profile 3.02
3. Support GSD 5.0 specification and standard EDD specification
4. Support AI, AO, DI, DO standard function block
5. Support up to 4 Modbus devices -
Hot
MODBUS To FF Gateway
G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber.
Email Details
1. Modbus-RTU protocol to FF H1 protocol
2. Comply with FF H1 protocol
3. Support LinkMaster function
4. Support standard DD specification
5. Support up to 4 Modbus devices -
Hot
Modbus to Gateway DP
Modbus to DP Gateway realizes the conversion function from Modbus RTU to PROFIBUS DP, making multiple slave station devices that conform to Modbus RTU communication regulation access to PROFIBUS DPnetwork. Modbus can be as master or slave, and this function can be realized by a special function button.
Email Details
1. Modbus-RTU protocol to PROFIBUS DP protocol
2. Standard DP interface, baud rate self-adapting, support up to 12Mbps
3. Support up to 244 byte input/output
4. Configure Modbus communication parameters by GSD
5. Modbus side can be both master and slave station -
Hot
HART To MODBUS Gateway
G1003 HART to Modbus Gateway
Email Details
1. HART protocol to Modbus-RTU/ASCII protocol
2. Hardware interface RS232/422/485
3. Configured as HART first master device or second master device
4. Can work in a point-to-point or multipoint mode
5. Connect up to 15 HART slave devices in multipoint working mode
6. All supported HART commands can be configured
7. Support HART burst mode -
Hot
G1100 WirelessHART Smart Gateway
G1100 WirelessHART Gateway
Email Details
1. Gain real-time process data. Reliability of wireless data can reach 99%
2. Modbus RTU/TCP, OPC & HART-IP connectivity
3. Comply with HART 7 protocol
4. Networks up to 250 devices
5. Class I, Division 2, Groups A, B, C and D T6
6. ATEX: II 3G Ex ec IIC T6 Gc
7. IECEx: Ex ec IIC T6 Gc
8. Explosion proof grade: Ex nA IIC T4 Gc -
Hot
LinkMaster Function Modbus to FF Gateway
LinkMaster Function Modbus to FF Gateway.G0313 Modbus to FF Gateway is a gateway device of Modbus protocol and FF protocol developed by Microcyber.
Email Details
1. Modbus-RTU protocol to FF H1 protocol
2. Comply with FF H1 protocol
3. Support LinkMaster function
4. Support standard DD specification
5. Support up to 4 Modbus devices -
Hot
Fieldbus Devices(Modbus to HART Gateway )
G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output.
Email Details