HART To MODBUS Gateway

  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • HART To MODBUS Gateway
  • video
HART To MODBUS Gateway
  • Microcyber
  • Liaoning, China
  • ASAP
  • 1000 units per month

G1003 HART to Modbus Gateway
1. HART protocol to Modbus-RTU/ASCII protocol
2. Hardware interface RS232/422/485
3. Configured as HART first master device or second master device
4. Can work in a point-to-point or multipoint mode
5. Connect up to 15 HART slave devices in multipoint working mode
6. All supported HART commands can be configured
7. Support HART burst mode

G1003 HART To MODBUS Gateway Product Description


HART To MODBUS Gateway

G1003 Brief Instruction

G1003 gateway realizes protocol converting from HART to Modbus RTU / ASCII. Supporting to connect multi HART slave devices into Modbus network. In the gateway, HART terminal is master station, Modbus terminal is slave station. 


G1003 HART To MODBUS Gateway Features & Structure


  • Be tallied with HART7.0

  • HART master and Modbus slave mode

  • 4~20mA analog signal overlay HART digital signal

  • Support 15 HART slave device

  • Configure gateway by special software

  • Write protect user data

  • RS485 Modbus interface

  • LED power and communication indicating

  • Standard DIN rail installation


G1003 Size

HART to Modbus Gateway


G1003 Structure

Gateway

G1003 Connection


HART To MODBUS Gateway

Function overview

The HART to Modbus gateway contains a HART master channel and a Modbus slave channel. HART master channel is in charge of obtaining HART slave data in HART network, and write the obtained data into data area inside the gateway; Modbus slave channel is responsible for receiving request from Modbus master station, including requests during configuring gateway parameter and loop reading data area inside the gateway; By the HART to Modbus gateway, easily realize the function that Modbus master station accesses to HART network data.


G1003 HART To MODBUS Gateway Basic Parameter


Parameter

Value

Working Temp.

-20 ... +70 °C

Storage Temp.

-20 ... +70 °C

Power Supply

9~30VDC

Dimension (L x W x H)

114.5 x 22.5 x 99 mm (without connector)

Modbus Interface

RS-232/RS-422/RS485

HART Interface

HART digital signal

Indicator Light

SYS, APL, L/A, Rx/Tx, bus-specific

Weight

150 g

Protocol before conversion 

HART

Protocol after conversion

Modbus

EMC

GB/T 18268.1

Noise Interference

GB 9254

Installation

DIN-Rail, EN-50022 35mm x 7,5mm



G1003 HART To MODBUS Gateway Application


HART to Modbus Gateway

G1003 HART To MODBUS Gateway Package and Delivery


Gateway

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy