Built-in Modules
Built-in Modules 1.Transmitter accuracy achieves 0.05% 2.Support many types of thermal resistance and thermocouple sensors 3.Thermocouple can use cold end compensation function 4.Support 2/3/4-wire RTD connection mode 5.Safety isolation for bus and sensor
-
Hot
MODBUS To PA Module
M0307 MODBUS To PA Module.M0307 Modbus to PA embedded module is one of the Microcyber M-series embedded modules developed by Microcyber Corporation.
Email Details
1. Size: 42mm*65mm
2. Comply with PA profile 3.02
3. Support Modbus-RTU communication parameters dynamic configuration
4. Support AI, AO, DI and DO function blocks
5. Support up to 4 channels AI, AO, DI, DO -
Hot
MODBUS To FF Module
M0313 MODBUS To FF Module.Modbus-FF built-in module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol.
1. Size: 42mm*65mm
2. Comply with FF H1 protocol
3. Support Modbus-RTU communication parameters dynamic configuration
4. Support AI, AO, DI, DO and PID function blocks
5. Support ITK 6MODBUS To FF Module Modbus-RTU device to FF device variable output MODBUS Protocol to Foundation Fieldbus F1Email Details -
Hot
HART Module Modbus to HART Module
Microcyber Corporation (hereinafter referred to as “Microcyber”) has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.
Email Details -
Hot
Modbus to DP Built-in Module
Modbus to DP Built-in Module is one of the Microcyber M-series embedded modules developed by Microcyber Corporation. This series of embedded modules have features like same size, same interface, easy to upgrade, easy configuration and so on, it is the ideal choice for users to quickly develop the fieldbus equipment.
Email Details -
Hot
Modbus to PA Built-in Module
Modbus to PA built-in module is one of the Microcyber M-series built-in modules developed by Microcyber Corporation. This series of built-in modules have features like same size, same interface, easy to upgrade, easy configuration and so on, and Modbus to PA built-in module is the ideal choice for users to quickly develop the fieldbus equipment.
Email Details
1. Size: 42mm*65mm
2. Comply with PA profile 3.02
3. Support Modbus-RTU communication parameters dynamic configuration
4. Support AI, AO, DI and DO function blocks
5. Support up to 4 channels AI, AO, DI, DO -
Hot
Modbus to FF Built-in Module
Modbus to FF Built-in Module realizes the conversion function from MODBUS Protocol to Foundation Fieldbus F1 Protocol. Modbus to FF Built-in Module is one of the Microcyber M-serise modules,which have features of same size,same interface,easy to upgrade and easy to configure
Email Details -
Hot
MODBUS To DP Module
M0306 Modbus to DP Module
Email Details
1. Size: 42mm*65mm
2. Modbus-RTU master station, PROFIBUS DP slave station
3. Comply with PROFIBUS DPV0 protocol
4. Electrical interface connected with Modbus-RTU slave is TTL level
5. Can set PROFIBUS DP slave station address via DIP switch
5. Same hardware, M0006 custom protocol to DP module -
Hot
MODBUS To HART Module
MODBUS To HART Module/M0310 General Instroduction
Email Details
Microcyber Corporation has customized many built-in protocol converting modules for the majority of field device manufacturers, supporting to connect MODBUS RTU protocol (hereinafter referred to as “MODBUS” protocol) slave device into a variety of fieldbus system. The function of M0310 built-in MODBUS to HART module (hereinafter referred to as "HART module") is to convert MODBUS slave device into HART slave device.