Fieldbus to Current Converter
NCS-FI105 fieldbus to current Converter is used to convert fieldbus signals to conventional analog signals. It can receive fieldbus signals, and convert them to 4-channel 4~20mA analog signals. NCS-FI105 is the converter between fieldbus system and control valve/other actuator.

Product overview

NCS-FI105 fieldbus to current Converter is used to convert fieldbus signals to conventional analog signals. It can receive fieldbus signals, and convert them to 4-channel 4~20mA analog signals. NCS-FI105 is the converter between fieldbus system and control valve/other actuator. NCS-FI105 is an intelligent instrument and complies with FF Fieldbus Specification. It can be interlinked with several FF equipment. 


Features

  • Number of channels:4

  • Output of signal:4-20mA

  • Bus signal:31.25kbit/s

  • Power:9-32VDC

  • Current consumption(static):≤ 14mA


Details

signal to analog converter

Parameters

Parameter

Value

Input signal

4~20mA

Channels

4 Channels

Current output  

NPN collector output

Power supply

9 ~ 32 VDC ;Current Dissipation (static): ≤ 14mA

Fieldbus Signal

Communication Baudrate 31.25kbit/s, current-mode

Insulation

Between housing and terminal board:

500 Vrms (707 VDC)

Display

6 bits digital number and 5 bits characters LCD display (Optional)

Temperature range

- 40 ~ 85℃ (No display)

- 30 ~ 70℃ (display)

Humidity Range

0% ~ 100% RH

Start Time

≤ 5s

Protection grade

IP 65

EMC

Designed to comply IEC 61000


Size

Fieldbus to 4-20mA Converter

Certification

Profibus to 4-20mA Converter



Packaging&Shipping

signal to analog converter