NCS-PT105IIS PA/FF Protocol Pressure Transmitter (Piezoresistance Silicon Sensor)
- Microcyber
- Liaoning, China
- In Stock
- 500 Sets/Month
NCS-PT105IIS PA/FF Protocol Pressure Transmitter
1. Support the latest versions of FF H1, PROFIBUS PA, PROFIBUS DP and HART protocols
2. Pressure types include gauge pressure, absolute pressure
3. High precision: ±0.075% SPAN
4. Long term stability: ±0.1% URL within 12 months
5. FCG FF interoperability test certification, PNO interoperability test certification (PA profile 3.02) and FCG HART interoperability test certification (HART 7), comply with DPV0 and DPV1 protocol
6. Explosion-proof (intrinsically safe, flameproof) certification
NCS-PT105IIS series Smart Pressure Transmitter with advanced, mature, reliable Piezoresistive Silicon Sensors has been designed meticulously by combining advanced microprocessor technology and digital capacitance measurement techniques. Its LCD can display many physical parameters such as pressure, temperature, current. It can be realized zero adjustment, range settings and other features by key-press operation, and easy to on-site tests.
NCS-PT105IIS series Smart Pressure Transmitter supports HART, FF H1, Profibus PA, Profibus DP protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.
NCS-PT105IIS series Smart Pressure Transmitter Specification:
Basic Parameter | |
Measure object | liquid、gas、stream |
Power | 9~32V dc (FF 、 PA) 9~17.5VDC (FF、PA; explosion-proof) 11.9~42VDC (HART) 11.9~30VDC (HART; explosion-proof) |
Output | Analog:2 wire 4~20mA Digital:HART,FF and PA signal |
Load resistant | 0~1500ohm (common) 250~550ohm (use HART) |
Insulation | Voltage between terminal and housing:500Vrms (707VDC) |
Display | Optional 6 bits digital number or 5 bits characters LCD display |
Temperature | Work temperature: -40 ~ 85℃ (without display) -30 ~ 70℃ (with display) -30 ~ 60℃(explosion-proof IC) Store temperature: -40 ~ 100℃ (without display) -40 ~ 85℃ (with display) |
Humidity scale | 5%~100%RH |
Start time | ≤ 5 seconds |
Refresh time | 0.2 seconds |
Dump adjusting | Constant of time 0~15 seconds |
Performance Specification | |
Precision | ±0.075% of the select range. If the select range <1/10 maximum of the range, the precision is ±[0.025+0.005× (maximum range/select range)]% of select range |
Temperature Effect | Effect of every change of 28℃ (50℉) Select range ≥0.1 maximum range:±[0.019% of maximum range +0.125% of select range] ; Select range <0.1 maximum range:±[0.025% of maximum range+0.125% of select range]. |
Long Time Stability | In 12 months, ±0.1% of maximum range |
Static Pressure Effect | ±0.25%/13.8MPa of maximum range |
Location Installed Effect | The maximum of the zero point movement is 0.24kPa |
Power Effect | < 0.005%/V of range calibrated |
Explosion-proof | intrinsically safety Ex ia II C T4 |
Proof Level | IP65 |
Vibration Effect | IEC 60068-2-6 Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal) |
Electromagnetic Compatibility | IEC 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test IEC 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency,electromagnetic field immunity test IEC 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test IEC 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
NCS-PT105IIS series Smart Pressure Transmitter Dimension&Structure: