HART DIN Rail Temperature Transmitter

  • HART DIN Rail Temperature Transmitter
  • HART DIN Rail Temperature Transmitter
  • HART DIN Rail Temperature Transmitter
  • video
HART DIN Rail Temperature Transmitter
  • Microcyber
  • China
  • In Stock
  • 500 Sets/Month

NCS-TT106-R1 fieldbus temperature transmitter, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control.
1. Support 4 types of thermal resistance and 8 types of thermocouple
2. Thermal resistance supports 2-wire, 3-wire and 4-wire
3. The cold junction compensation accuracy of voltage signal can reach ±0.15℃
4. High precision (better than grade 0.1), low temperature drift (better than±50ppm/℃ )
5. FCG interoperability test certification (ITK 6), PNO interoperability test certifi-cation (PA profile 3.02), and FCG HART interoperability test certification (HART 7)
6. CE, explosion-proof (intrinsically safe, flameproof) certification


HART DIN Rail Temperature Transmitter(NCS-TT106H-R1): uses digital technology, so it can connect with many types of thermocouple and thermo resistive sensors. It has wide range and simple interface between field and control room, which reduces the expense of installation, operation and maintenance.


HART DIN Rail Temperature Transmitter Basic Parameter

Input Signal:

Pt100、Pt1000、CU50、CU100、0~500Ω、0~4000Ω

B,E,J,N,K,R,S,T eight kinds of Thermocouple

-100mV~100mV voltage signal

Channel: Single

RTD Wiring: 2-wire, 3-wire, 4-wire

Bus Power: HART: 11~35 VDC

Bus Signal: HART: current mode

Electric Isolation: 1000VAC

Working Temperature: -40℃~85℃

Humidity Range: 5%~95%RH

Start Time: ≤5s

Refresh Time: 0.5s

EMC: GB/T 18268.1-2010

Protection: Terminal IP00, housing IP20

Voltage effect: ±0.005%/V

Alarm signal:

Alarm output can be set as 3.5…23 mA

Upper/lower limit current 20.8mA / 3.8mA

Current Accuracy: 0.03%


HART DIN Rail Temperature Transmitter RTD Parameter

RTD Parameter at Normal Temperature


Transmitter


RTD Other Parameter

Wiring: 2、3、4

Common Mode Rejection: ≥70dB (50Hz and 60Hz)

Series Mode Rejection: ≥70dB (50Hz and 60Hz)


HART DIN Rail Temperature Transmitter Thermocouple

Thermocouple Parameter at Normal Temperature


Temperature

transmitter


HART DIN Rail Temperature Transmitter Thermocouple Other Parameter

Compensation Accuracy: ±0.5℃

Sensor Type: B,E,J,N,K,R,S,T;-100mV~+100mV

Common Mode Rejection: ≥70dB(50Hz and 60Hz)

Series Mode Rejection: ≥70dB(50Hz and 60Hz)

Temperature Effect: <50ppm/℃


HART DIN Rail Temperature Transmitter Physical Parameter

Dimension: 22.5*110*99mm

Housing Material: Nylon


HART DIN Rail Temperature Transmitter Dimension


Transmitter

Dimension of Temperature Transmitter (Unit: mm)


HART DIN Rail Temperature Transmitter Wiring

Temperature

HART DIN Rail Temperature Transmitter Wiring

Fieldbus temperature transmitter power and bus signal share a pair of cable, and it is called bus cable. It is suggested the user use fieldbus special cable recommended by IEC61158-2.

The signal cable and bus cable cannot share wires or wire slot with other device power wire, and they shall be away from device with high power.

The shielded wires of bus ends shall be connected to the ground.

 

HART TEMPERATURE TRANSMIITER CONFIGURATION

 

HART DIN Rail Temperature Transmitter Topology Connection

The connection mode of HART smart transmitter can be divided into 4~20mA compatible mode and networking mode.

4~20mA compatibility mode

transmitter


HART DIN Rail Temperature Transmitter Features:

1) Access to the upper level control system through the AI module and HART communication device;

2) Mixed use of analog and digital communication methods;

3) The device address is 0.

 

HART DIN Rail Temperature Transmitter Networking mode (as shown in picture)

Transmitter

HART DIN Rail Temperature Transmitter Features:

Access to the upper level control system through the HART communication device;

Using only the digital function of the HART system, the current on the line is fixed at 4 mA;

Supports up to 64 device networking in short address format.

 

HART DIN Rail Temperature Transmitter FAQ

Q: Can I get a free electronic manual?

A: Yes, if you want it, please contact us.

 

Q: Can you provided OEM service?

A: Yes, we can, such as communication board, we can also provided fieldbus development toolkit.

 

Q: How to maintenance NCS-TT106H-R1 HART DIN Rail Temperature Transmitter?

A: No communication--Temperature Module Connection:Check the bus cable connection Check bus power polarity and check bus cable shield, whether it is single point earthing or not

 

Hot Products--HART DIN Rail Temperature Transmitter

TemperaturetransmitterTransmitterTemperature

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right