MCAFD8 Active Fieldbus Distributor is suitable for the FF H1 and PROFIBUS PA fieldbus application.Through the distributor, field devices use the topology of the main - branch to connect the system. Each distributor has eight branches.There’s built-in automatic bus terminal. LED status indicator can rapidly diagnosis main line and branch line short circuit state, isolate the fault section automatically. Multiple protection function of the distributor can ensure the safe operation of the system.
MCAFD4 Active Fieldbus Distributor
Feature
Short-circuit, overload protection for main line and branch line
Suitable for FOUNDATION Fieldbus H1 and PROFIBUS PA
LED indicator fault diagnosis
Automatic bus terminal
Reverse connection protection
Automatic isolating fault port
Protection class IP65
MCAFD4 Active Fieldbus Distributor System Wiring Diagram
MCAFD4 Active Fieldbus Distributor Parameters
Technical Index
Power Consumption
No-Load Current Loss: <10mA
Power Consumption: <180mW
Main Line
Number of Electrical Connectors 2
Electrical Connectors: M16*1.5
Cable Diameter: 4~9mm
Terminals: Screw type PCB Terminal (3-Pin)
Bus Input Voltage: 10~32VDC
Main Line Max. Output Current: 1A
Main Line Voltage Drop: <0.3V
Branch
Number of Electrical Connectors: 4
Num. of Connectable Field Devices: 4
Electrical Connectors: M16*1.5
Cable Diameter: 4~9mm
Teminals: Screw type PCB terminal (3-pin)
Branch Output Voltage: 9~31VDC
Branch Max. Output Current: 60mA
Short-Circuit Protection Current: <300uA
Main and Branch Voltage Drop: <1V
Interface
Environmental Characteristics
Working Temperature: -40℃~+85 ℃
Storage Temperature: -40℃~+85 ℃
Relative Humidity: 5%RH~95%RH
Protection Degree IP65
Dimension W x H x D (mm): 125*57*80 (No electrical connector)
Weight: 600g
MCAFD4 Active Fieldbus Distributor Parameters Installation & Wiring
LED indicating of MCAFD4 Active Fieldbus Distributor
Terminal distribution of MCAFD4 Active Fieldbus Distributor
Wiring of MCAFD4 Active Fieldbus Distributor
1. Connect bus through T1 & T2, T1 for bus input, T2 for bus ouput, and connect fieldbus devices by branch S1 to S4.
2. Open cover of active fieldbus distributor, and install the distributor to the flat surface or on the guide rail, to ensure 60 mm space connection on the rear left of and below the distributor.
3. Unscrew the electrical connector, run the fieldbus cable through the electrical connector gland, and twist the cable onto the corresponding terminal, to ensure correct polarity of the connection.
4. Close the active fieldbus distributor cover, tighten the fixing screw.
5. Use seal plug to seal unused cable entry gland, so as to ensure the IP65 protection class.
MCAFD8 Fieldbus Junction Box
The MCAFD8 active fieldbus distributor is suitable for FF-H1 and PROFIBUS PA fieldbus should be used to connect field equipment to the system in a main-branch topology through the distributor, each of which has eight branches, built-in automatic bus terminal, LED status the indicator can quickly diagnose the short circuit status of the main line and secondary line, automatically isolate the fault section, and ensure the safe operation of the system with multiple protection functions of the distributor.
MCAFD8 Fieldbus Junction Box Feature
Short-circuit, overload protection for main line and branch line
Suitable for FOUNDATION Fieldbus H1 and PROFIBUS PA
LED indicator fault diagnosis
Automatic bus terminal
Reverse connection protection
Automatic isolating fault port
Protection class IP65
MCAFD8 Fieldbus Junction Box System Wiring Diagram
MCAFD8 Fieldbus Junction Box Parameters
Power Consumption
No-Load Current Loss: <15mA
Power Consumption: <240mW
Main Line
Number of Electrical Connectors: 2
Electrical Connectors: M16*1.5
Cable Diameter: 4~9mm
Teminals: Screw type PCB terminal (3-pin)
Bus Input Voltage: 10~32VDC
Main Line Max. Output Current: 1A
Main Line Voltage Drop: <0.1V
Branch
Number of Electrical Connectors: 8
Num. of Connectable Field Devices: 8
Electrical Connectors: M16*1.5
Cable Diameter: 4~9mm
Teminals: Screw type PCB terminal (3-pin)
Branch Output Voltage: 9~31VDC
Branch Max. Output Current: 60mA
Short-Circuit Protection Current: <300uA
Main and Branch Voltage Drop: <1V
Environmental Characteristics
Working Temperature: -40℃~+85 ℃
Storage Temperature: -40℃~+85 ℃
Relative Humidity: 5%RH~95%RH
Protection Degree: IP65
Dimension W x H x D (mm): 250*57*80 (No Electrical Connector)
Weight: 1200g
MCAFD8 Fieldbus Junction Box Installation & Wiring
LED indicating of MCAFD4 Active Fieldbus Distributor
Terminal Distribution of MCAFD8 Active Fieldbus Distributor
Wiring of MCAFD8 Active Fieldbus Distributor
1. Connect bus through T1 & T2, T1 for bus input, T2 for bus ouput, and connect fieldbus devices by branch S1 to S8.
2. Open cover of active fieldbus distributor, and install the distributor to the flat surface or on the guide rail, to ensure 60 mm space connection on the rear left of and below the distributor.
3. Unscrew the electrical connector, run the fieldbus cable through the electrical connector gland, and twist the cable onto the corresponding terminal, to ensure correct polarity of the connection.
4. Close the active fieldbus distributor cover, tighten the fixing screw.
5. Use seal plug to seal unused cable entry gland, so as to ensure the IP65 protection class.