Modbus to PA Gateway

14-02-2023

The product realizes the converter function from Modbus RTU to PROFIBUS PA, and it shall multiple devices with Modbus RTU protocol to PROFIBUS PA network.


Modbus to PA Gateway Device Types

According to Modbus interface, the gateway shall have 2 models:

Product Model

Modbus Interface

GW-MODB-PA-RS485

RS485

GW-MODB-PA -RS232

RS232


Modbus to PA Gateway Dimension

temperature transmitter

Modbus to PA Gateway Structure


Pressure Transmitter


1

Pasting

2

Upper Cover

3

Interface

Board

4

Hexagonal

Prisms

5

Wide Edge

Screw

6

Iron Wire

7

Clip

8

Wide Edge

Screw

9

Base

10

Communication

Board





Modbus to PA Gateway Working Principle

G0307 Modbus to PA gateway is a device supporting Modbus RTU protocol and PROFIBUS PA protocol. As the PROFIBUS PA slave device, it can make 4 Modbus slave devices connect to PROFIBUS PA network.


Intelligent pressure converter

temperature transmitterPressure TransmitterIntelligent pressure converter

G0307 Modbus to PA gateway includes 1 physical block, 16 function blocks and 1 Modbus transducer block. Modbus transducer block includes 4 AIs, 4 AOs, 4 DIs and 4 DOs. The data (Modbus device data) can establish connection with function blocks via channels to realize protocol convert function.


temperature transmitter


As Modbus master, G0307 Modbus to PA gateway shall do the communication with Modbus slave, and exchange Modbus transducer block parameter data and function block, so that it connect Modbus slave to PROFIBUS system.

Modbus to PA Gateway Technical Specification

Basic Parameter

Bus Power

9~32VDC

Modbus Power

24VDC(±20%)

Current Consumption

≤ 14mA

Working Temperature

-20℃~70℃

Storage Temperature

-40℃~70℃

Humility Range

5%~95%RH

Modbus

Physical Interface

 

RS485 (configurable end) / RS232


Performance Index

Protection Level

IP20 for housing

EMC

GB/T 18268.1-2010

GB/T 18268.23-2010


Physical Characteristic

Weight

0.2kg

 

Structure Material

Housing: ABS; Clip: POM

Coating: Polyester epoxy resin


Default Communication Parameter

Slave Address

1, 2, 3, 4

Baud Rate

9600

Data Bit

8

Stop Bit

1

Check

No check

CRC Check

High byte is ahead


Supportive Modbus Function Code

1

Read coils

2

Read discrete inputs

3

Read holding registers

4

Read input registers

5

Write single coil

6

Write single register

16

Write multiple registers values