NCS-TT105 HART Protocol Temperature Transmitter/High Precision Smart Temperature Transmitter
- Microcyber
- Shenyang,China
- 3 Work Days
- 1000Pieces/Month
NCS-TT105 adopts digital technology, which can be applied to a variety of thermal resistance and thermocouple sensors, with a wide range, simple interface between the field and the control room, and can greatly reduce the cost of installation, operation and maintenance.
Product Overview
NCS-TT105 smart temperature transmitter adopts fieldbus technology, is a new generation of fieldbus smart temperature transmitter, and is an indispensable field device in process control. The device integrates rich functional modules, which can realize both general detection functions and complex control strategies.
NCS-TT105 adopts digital technology, which can be applied to a variety of thermal resistance and thermocouple sensors, with a wide range, simple interface between the field and the control room, and can greatly reduce the cost of installation, operation and maintenance.
NCS-TT105 smart temperature transmitter supports HART, FF, PA protocol and can be widely used in petroleum, chemical, power plant, metallurgy and other industries.
The dimensions of the smart temperature transmitter:
The general assembly drawing:
Features
NCS-TT105 Smart Temperature Transmitter:
1. Support the latest versions of FF H1, PROFIBUS PA and HART protocols
2. Support dual-channel sensor input, support redundancy and hot backup
3. Thermal resistance supports 2-wire, 3-wire and 4-wire
4. The cold end compensation accuracy of thermocouple is ± 1.0℃
5. High precision (better than grade 0.1), low temperature drift (better than ± 50ppm/℃)
6. Enhanced type: ±0.1℃ (Pt100, Pt1000)
Details
Signal conversion
Parameter
Parameter | Value |
Input Signal | Resistance: PT100, PT1000, CU50, CU100, 0~500Ω, 0~4000Ω |
Thermocouple: B, E, J, N, K, R, S, T | |
Voltage signal: -100mV~100mV | |
Channels | 2 Channels |
RTD connection | 2, 3 wire |
Power Supply of Fieldbus | FF/PA:9~32 VDC/Current : ≤ 14mA |
HART: 12~42VDC | |
Insulation | Between housing and terminal board: |
500 Vrms (707 VDC) | |
Display | 6-digit numeric and 5-digit alphabet LCD Display |
Operation Temperature | -40 ~ 85℃ (Without display) |
-30 ~ 70℃ (With display) | |
Humidity Range | 0% ~ 100% RH |
Start Time | ≤ 5s |
Update Time | 0.2s |
Protection grade | IP 65 |
EMC | Designed to comply IEC 61000 (GB/T 18268-2000) |
HART networking mode
Certification
Packaging &Shipping